| Fault Code |
Fault Message |
Fault Details | Recommended Measures |
| 00 | No error | No error | No action necessary |
| 01 | Defective control unit | Defective control unit, wrong end-of-line programming or coolant temperature sensor (at water heaters) failure | Replace control unit |
| 02 | No start | After start-up has been repeated, combustion still fails to occur |
1) Check for faults in the air intake and exhaust systems 2) Check for faults in fuel system 3) Check the fuel pump 4) Electrical check of glow plug |
| 03 | Flame failure | The flame went out during operation and combustion |
See error 02 |
| 04 | Supply Voltage too high | The supply voltage was too long above the maximum threshold value | Check system voltage |
| 05 | The flame was detected prior to combustion |
Flame detector signals flame before combustion operation |
1) Check for fault in the air intake, exhaust systems 2) Check for faults in the fuel system 3) Check the fuel pump 4) Electrical check of glow plug |
| 06 | Heating unit overheated | Overheat protection has been activated or the temperature at the the heat exchanger has exceeded the upper limit |
1) Check for fault in air intake/blowout side, exhaust systems 2) Check for faults in the fuel system |
| 07 | Heater lock-out | Heater interlocked | 1) Reset heater lock-out and attempt restart 2) Read out further fault messages and work through instructions Reset heater lock-out: switch on the heater. Pull fuse F1 for at least 10 s. Switch off the heater. Reinsert fuse F1. Switch on the heater. NOTE The following fault occurred several times: Fault counter: > 10x False start counter: > 7x Overheating counter: > 20x |
| 08 | Fuel pump short circuit | The fuel pump has a short circuit to ground |
Electrical check of fuel system |
| 09 | Combustion air fan short circuit | The combustion air fan has short circuit to ground |
Electrical check of combustion air fan motor |
| 11 | Wrong fuel coding | Incorrect parameter block or wrong heater (diesel/gasoline) used |
Replace control unit |
| 12 | W-bus communication failure |
W-bus communication failure |
1) Check for fault in area of W-bus communication/W-bus control element/W-bus Telestart 2) Replace control unit |
| 14 | Temperature sensor short circuit (internal, external) | The temperature sensor has short circuit to ground |
Electrical check of external/internal temperature sensor |
| 15 | Combustion air fan blocked | Combustion air fan blocked | 1) Check for fault in fan motor 2) Heating air intake fan wheel snagging or jammed 3) Combustion air intake fan wheel snagging or jammed |
| 17 | Gradient exceedance overheat protection |
The temperature rise at the heat exchanger has exceeded the upper limit. | Check for fault in air intake/blowout side, exhaust systems |
| 18 | Communication failure on customer-specific bus | Communication failure on customer specific bus | - |
| 19 | Glow plug/flame monitor short circuit | Glow plug / electronic ignition unit has a short circuit to ground | Electrical check of glow plug |
| 81 | EOL checksum error | The checksum of EOL dataset is wrong | Replace control unit |
| 82 | No start during test-run | No start during test-run | See error 02 |
| 83 | Flame failure | Flame interruption during combustion operation, more than FAZ (EEPROM) times. |
See error 02 |
| 84 | Operating voltage too low | The supply voltage was too long below maximum threshold value |
Check system voltage |
| 88 | Fuel pump interruption | Fuel pump interrupted or short circuit to supply voltage UB |
Electrical check of fuel system |
| 89 | Combustion air fan interruption |
Combustion air fan interrupted or short circuit to supply voltage UB | Electrical check of fan motor |
| 91 | Wrong control unit coding | Control unit locked or coded as neutral | Replace control unit |
| 92 | Command refresh failure | Command refresh failure | Check for fault in the area of W-bus communication/W-bus control element/W-bus Telestart |
| 94 | Temperature sensor interruption (internal, external) |
Temperature sensor interrupted or short circuit to supply voltage UB |
Electrical check of external/internal temperature sensor |
| 97 | Gradient undershooting during start | Overheat sensor position wrong (temperature gradient too low) |
1) Check position of overheating sensor 2) Check fuel supply system |
| 99 | Glow plug / electronic ignition unit interruption |
Glow plug / electronic ignition unit interrupted or short circuit to supply voltage UB |
Electrical check of glow plug |
| 0 A | Glow plug/flame monitor short circuit | Glow plug/Flame monitor circuit has a short circuit to ground | Electrical check of glow plug |
| 1 A | Flame sensor short circuit | The flame sensor has a short circuit to ground |
Electrical check of flame monitor |
| 1B | Overheat sensor short circuit |
The overheat sensor has a short circuit to ground |
Electrical check of overheating sensor |
| 8 A | Glow plug / electronic ignition unit interruption |
Glow plug/Flame monitor interrupted or short circuit to supply voltage UB |
Electrical check of glow plug |
| 9 A | Flame sensor interruption | Flame sensor interrupted or short circuit to supply voltage UB |
Electrical check of flame monitor |
| 9B | Setpoint potentiometer interruption | Setpoint potentiometer interrupted or short circuit to supply voltage UB |
Electrical check of setpoint sensor |
| AB | Overheat sensor interruption |
Overheat sensor interrupted or short circuit to supply voltage UB |
Electrical check of overheating sensor |
| F00 | Defective control unit | Control unit defective EOL programming error |
1) Check for fault in area of the W-bus communication/W-bus control element/W-bus Telestart 2) Replace the control unit |
| F01 | No start | No flame formed even after a repeated start attempt | 1) Check for faults in air intake and exhaust systems 2) Check for faults in fuel system 3) Check the fuel pump 4) Electrical check of glow plug |
| F02 | Flame failure | The flame goes out during operation and no longer reformed after a restart attempt. |
See error 01 |
| F03 | Supply Voltage too high | The operating voltage was higher than the maximum permissible value for too long | Check system voltage |
| F04 | The flame was detected prior to combustion |
The flame monitor detected a flame before combustion started |
1) Check for fault in air intake, exhaust systems 2) Check for fault in fuel system 3) Check fuel pump 4) Electrical check of glow plug |
| F05 | Flame sensor interruption | There is a break or short to UB in the electrical circuit of the flame detector |
Electrical check of flame monitor |
| F06 | Temperature sensor interruption (internal, external) |
There is a break or short to UB in the temperature sensor | Electrical check of external/internal temperature sensor |
| F07 | Fuel pump interruption | There is a break or short to UB in the electrical circuit of the fuel pump |
Electrical check of fuel system |
| F08 | Combustion air fan short circuit | The combustion air fan has a short to the ground or the fan motor is overloaded |
Electrical check of combustion air fan motor |
| F08 | Combustion air fan blocked | Combustion air fan blocking guard has tripped |
1) Check for fault in fan motor 2) Heating air intake fan wheel snagging or jammed 3) Combustion air intake fan wheel snagging or jammed |
| F09 | Glow plug / electronic ignition unit interruption |
There is a break or short to UB in the glow plug/ignition spark generator |
Electrical check of glow plug |
| F10 | Heating unit overheated | Overheating lock-out has tripped (heater overheated) | 1) Check for fault in air intake/blowout side, exhaust systems 2) Check for fault in fuel system |
| F11 | Overheat sensor interruption |
There is a break or short to UB in the electrical circuit of the overheating sensor |
Electrical check of overheating sensor |
| F12 | Heater lock-out | Heater lock-out was activated | 1) Reset heater lock-out and attempt restart 2) Read out further fault messages and work through instructions Reset heater lock-out: switch on heater. Pull fuse F1 for at least 10 s. Switch off heater. Reinsert fuse F1. Switch on the heater. NOTE The following fault occurred several times: Fault counter: > 10x False start counter: > 7x Overheating counter: > 20x |
| F14 | Gradient undershooting during start | Wrong position of overheating sensor (overheating sensor gradient too small) |
1) Check the position of overheating sensor 2) Check the fuel supply system |
| F15 | Setpoint potentiometer interruption |
There is a break or short to UB in the electrical circuit of the setpoint potentiometer |
Electrical check of setpoint sensor |
Webasto Air Top 2000 STC Air Heater Fault Codes
Owner's Guide7 min read
Related guides
Keep reading
How to use your Webasto Air Top 2000 STC Diesel Heater + SmartControl
Webasto SmartControl & MultiControl Operating Instructions
Webasto SmartControl & MultiControl Operating Instructions
Dewinterising your campervan: How to get your vehicle ready for the new camping season
With the winter chill now subsiding, and the first signs of spring starting to emerge, your thoughts might be turning towards using your campervan again. Check out our…
How do I monitor my electricity usage in my campervan when using the solar panel?
Available for Android and iOS devices, the PVMobileSuite app uses your device's Bluetooth connectivity to connect to your solar panel controller and your leisure batte…
CamperKing Southwest · Paignton showroom
Want to see how it works in person?
Browse our current CamperKing stock or call our Paignton team for straightforward advice.